Three-zone Thermal Shock Test Chambers adopts a three-box structure, utilizes a pneumatic valve to switch the connection between a test area and a cold area, and between the testarea and a thermal area.
TECHNICAL FEATURES
Type | TOT- 80GXL |
TOT- 80GXL |
TOT- 80IXL |
TOT- 150EXL |
TOT- 150GXL |
TOT- 150IXL |
TOT- 252EXL |
TOT- 252GXL |
TOT- 252IXL |
TOT- 336EXL |
TOT- 336GXL |
TOT- 336IXL |
TOT- 450EXL |
TOT- 450GXL |
TOT- 450IXL |
|
Test Area Size | 500*400*400 | 600*500*500 | 700*600*600 | 800*700*600 | 800*800*700 | |||||||||||
Impact Temperature |
Low Temperature Impact Range |
-10℃~ -40℃ |
-10℃~ -55℃ |
-10℃~ -65℃ |
-10℃~ -40℃ |
-10℃~ -55℃ |
-10℃~ -65℃ |
-10℃~ -40℃ |
-10℃- -55℃ |
-10℃~ -65℃ |
-10℃~ -40℃ |
-10℃~ -55℃ |
-10℃~ -65℃ |
-10℃~ -40℃ |
-10℃~ -55℃ |
-10℃~ -65℃ |
High Temperature Impact Range |
60℃~150℃ | |||||||||||||||
Preheating Zone Heating Rate | ≥3℃/min | |||||||||||||||
Pre-cooling Zone Cooling Rate | ≥1℃/min | |||||||||||||||
Pre-cooling Zone Temperature Range | -10℃~ -60℃ |
-10℃~ -70℃ |
-10℃~ -77℃ |
-10℃~ -60℃ |
-10℃~ -70℃ |
-10℃~ -77℃ |
-10℃~ -60℃ |
-10℃~ -70℃ |
-10℃~ -77℃ |
-10℃~ -60℃ |
-10℃~ -70℃ |
-10℃~ -77℃ |
-10℃~ -60℃ |
-10℃~ -70℃ |
-10℃~ -77℃ |
|
Pre-heating Zone Temperature Range | 60℃~180℃ | |||||||||||||||
Dwell Time | ≥30min | |||||||||||||||
Recovery Time | Revert to ±2C in 5 Minutes | |||||||||||||||
Temperature Fuctuation | ≤1℃ | |||||||||||||||
Temperature Resolution | 0.1℃ | |||||||||||||||
Throttle Switching Time | ≤5s | |||||||||||||||
Cooling Method | Water-cooling | |||||||||||||||
Standard Reference | JESD22-A106B;GJB-150-A; MIL-STD-810G;MIL-STD-202G |
SOLUTIONS
- - New energy vehicles
- - Consumer electronics
- - Semiconductor industry
- - Photovoltalic energy storage
Contact GPower Vietnam for detailed information about the product and accompanying warranty and maintenance services.